B1 Error Code Troubleshooting and Solution
The B1 error code on a Goodman furnace indicates a compatibility issue between the blower motor and the control board, caused by mismatched software versions after replacement of the blower motor or the control board. If the control board has been replaced with the updated software, the older blower motor may no longer be compatible. Similarly, replacing the blower motor on the system with an old version of software on the control board will trigger B1 error. In case if repair needs to be done on equipment with older versions of software both the ECM blower motor and control board need to be replaced , in addition this repair might require additional software update . If update is required ED0 error will appear, for programming additional hardware is needed data sharing device -BTSDL01 to share software to the new board or ECM motor through the CoolCloud HVAC app.
B7 Error Code Troubleshooting and Solution
The B7 error code signals a failure in the furnace’s blower motor or control board, often caused by mechanical or electrical faults in the motor or malfunctioning communication from the control board. Loose wiring or obstructed airflow may also trigger this error, so ensure all connections are secure and the blower wheel is clean and unobstructed. For accurate diagnosis and resolution, consulting a qualified HVAC technician.